SynLube 100% SYNTHETIC COOLANT SYSTEM
This system of coolant products includes:
SynLube Synthetic 100% Coolant/Anti-Freeze is a single-phase, ethylene glycol type heavy duty engine coolant based on patented carboxylate corrosion inhibitor system with nitrite.
SynLube
Coolant Life Extender is the prescribed additive package recharge for SynLube Synthetic
Coolant/Anti-Freeze . Use SynLube Synthetic
100% Coolant/Anti-Freeze should you need to adjust the freeze point as required
by ambient conditions.
Product Application
|
| 300,000 miles on-road use (three years or 6,000 hours off-highway use) on initial fill | |
| Additional 300,000 miles on-road use (three years or 6,000 hours off-highway use) by adding SynLube Coolant Life Extender | |
| Easy maintenance | |
| No inhibitor level testing required | |
| Excellent pitting protection for wet sleeve cylinder liners | |
| Effective, long term corrosion protection for aluminum, brass, cast iron, steel, solder, and copper | |
| Improved water pump seal life due to reduced water pump seal wear resulting from fewer dissolved solids | |
| No silicate dropout or gel formation during use or storage | |
| Excellent heat transfer | |
| Reduced hard water scale | |
| Superior protection in high operating temperatures | |
| Protects against winter freeze up and minimizes the chance of summer boil over | |
| Outstanding hot surface aluminum protection | |
| Suitable for gasoline powered automotive and industrial engines | |
| 100% biodegradable in its pure unused form | |
| Compatible with conventional antifreeze. Dilution with conventional antifreeze will reduce long life benefits. SynLube recommends that this product is not diluted by more than 10% with conventional coolants. |
![]()
SynLube Synthetic
Coolant System is recommended for all heavy duty and natural gas engines
including Caterpillar, Navistar, Cummins, Detroit Diesel, Mack, MTU, and other original
equipment manufacturers (OEMs). SynLube
Synthetic Coolant System is especially recommended
for use in the cooling systems of all types of industrial internal combustion engines
including systems containing large amounts of aluminum alloys.
SynLube Synthetic
Prediluted 50% Coolant/Anti-Freeze
meets or exceeds:
| ASTM D 4656 for automotive service | |
| ASTM D 5345 for heavy duty diesel service |
SynLube Synthetic
100% Coolant/Anti-Freeze
(for freeze point adjustment only) meets or exceeds the requirements:
| ASTM D 3306 for automotive service | |
| ASTM D 4985 for heavy duty diesel service | |
| TMC RP 329 |
SynLube Synthetic
Coolant System meets:
| Phosphate free requirement of European OEMs | |
| Silicate free requirement of Japanese OEMs | |
| Caterpillar EC-1 | |
| Navistar B1, Type 3 |
ASTM D 1384 Glassware Corrosion Test
Weight loss in milligrams per coupon, negative indicates net gain
| Copper | Solder | Brass | Steel | Iron | Aluminum | |
| SynLube Synthetic Prediluted 50% Coolant/Anti-Freeze | 2 |
0 |
-1 |
-1 |
-1 |
3 |
| ASTM Limits (Max.) | 10 |
30 |
10 |
10 |
10 |
30 |
![]()
Traditional phosphate and borate containing coolants exhibit high pH
and reserve alkalinity (RA) when compared with SynLube Synthetic
Coolant/Anti-Freeze.
SynLube Synthetic
Coolant's unique corrosion inhibitor system is designed to protect aluminum
and other system metals at lower pH levels than conventional
coolants. A comparison of SynLube Synthetic Coolant/Anti-Freeze versus traditional coolants
is shown below.
| SynLube Synthetic Coolant/Anti-Freeze |
Traditional Antifreeze/Coolant |
|
| Typical pH | 8.3 |
10.5 |
| Typical RA (ml) | 6.0 |
12.0 |
The above comparison should not be used to draw conclusions about the relative
corrosion protection of SynLube
Synthetic Coolant / Anti-Freeze versus conventional
coolants.
RA (reserved alkalinity) is defined as the
amount in milliliters (ml),
of 0.1 normal hydrochloric acid required to reduce the pH of 10 ml of antifreeze to 5.5.
Since RA is based upon the buffering curve of inhibitors which are not present in SynLube Synthetic
Coolants, we suggests that it is more important that initial pH value does not change drastically during
service interval versus using RA as a corrosion protection indicator.
The American Society for Testing Materials (ASTM) has recently eliminated RA level
requirements in both key antifreeze specifications: ASTM D3306 for automotive engines and
ASTM D4985 for heavy duty engines. This action by the ASTM acknowledges that coolants
which are not based on phosphate and borate can provide excellent corrosion protection for
cooling system metals.
| SynLube Synthetic Prediluted 50% Coolant/Antifreeze: |
| Boiling Protection, °F (C) (15 lb. pressure cap | 265 (129.4)°C |
| Freezing Protection, °F (C) | -34°F (-36.7)°C |
SynLube Synthetic
Prediluted 50% Coolant/Antifreeze
should be used as manufactured. No further dilution is recommended.
Because SynLube Synthetic 100% Coolant / Antifreeze and SynLube Synthetic
Prediluted 50% Coolant / Antifreeze is silicate free, it can be stored at least
8 years with no problem, providing that the container integrity is maintained.
Always dispose of used coolant in accordance with local, state and federal guidelines.
![]()
| SynLube Synthetic 100% Coolant/Anti-Freeze | Value |
| Code No. | 07997 |
| Appearance | Red |
| Specific gravity 60/60 °F | 1.130 |
| Freezing point, °F (ASTM D 1177) | |
| 50 vol % q.s. aqueous solution | -34°F |
| pH (ASTM D 1287), 1:2 dilution with water | 8.3 |
| Reserve Alkalinity (ASTM D 1121), as received | 6.0 |
| Silicate, % (as Anhydrous Alkali Metasilicate) | None |
![]()
For maximum protection against freezing in extremely cold areas,
a 60% solution can be used.
Adjust SynLube Synthetic Prediluted 50% Coolant/Antifreeze
by the table amounts with SynLube
Synthetic 100% Coolant / Anti-Freeze for freeze
protection to -59°F (-50.6°C).
Concentrations greater than 67% or less than 40% are not
recommended.
| Freeze Point Adjustments as Required by Ambient Conditions |
| Total System Capacity (Gal., Qt. or L) | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 |
| Amount of Concentrate (Gal., Qt. or L) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
![]()
| SynLube Coolant Life Extender | |
| Code No. | 07999 |
| Appearance | Red |
| Specific Gravity | 1.06 |
| Silicate, % | None |
SynLube
Coolant Life Extender has been specially formulated to double the life of SynLube Synthetic
Prediluted 50% Coolant/Anti-Freeze.
It should only be added at 300,000 miles of on-road use
(three years or 6,000 hours of off-highway use).
| Quantity of SynLube Coolant Life Extender needed @ 300,000 miles of on-road use (three years or 6,000 hours of off-highway use) . |
| Cooling System Capacity / Coolant Life Extender |
| Gallons (Liters) / Quantity |
| .75-1.0 2-4 2 ounces |
| 1.5-2 5-8 4 ounces |
| 3-4 11-16 8 ounces |
| 6-8 22-30 16 ounces |
| 8-13 30-49 1 quart |
| 13-22 49-83 1.5 quart |
| 22-30 83-114 2 quarts |
| 30-41 114-155 3 quarts |
| 41-52 155-197 4 quarts |
| 52-64 197-243 5 quarts |
SynLube
Coolant Life Extender should only be
used with
SynLube Synthetic
Coolant/Anti-Freeze.
![]()
SynLube recommends
thoroughly flushing (twice) your system with distilled water if you have been using
conventional coolants before you install SynLube
Synthetic Coolant System.
SynLube does not recommend
commercial flushes, but if significant deposits are visible use a SynLube Cooling System Flush. Follow the engine manufacturer's
flushing procedure and dispose of properly. Be sure to flush the system thoroughly with
distilled water twice afterwards. When changing SynLube
Synthetic Prediluted 50% Coolant/Anti-Freeze, flush
with distilled water only. Do not use commercial flushes. In the event that a commercial
flush is inadvertently used, completely flush the cooling system (twice) with distilled
water.
The primary limiting factor in the shelf life of a coolant is silicate instability.
Since silicate will eventually polymerize to silicate gel, all traditional silicate-based
coolants have a shelf life of about 12 to 18 months.
SynLube Synthetic
Coolant System is silicate-free and, therefore,
can be stored for extended periods (up to 8 years) provided the integrity of the container
is maintained.
![]()
Code 07997 SynLube Synthetic 100% Coolant/Anti-Freeze
Code 07998 SynLube Synthetic Prediluted 50% Coolant/Anti-Freeze
Code 07999 SynLube Coolant Life Extender
Code 02610 SynLube Cooling System Flush Concentrate
Code 00006 SynLube Ultra Pure Synthetic Water
Code 00845 SynLube Coolant Sealer Liquid
![]()
| Description | SKU # |
Packaging |
Price* |
|---|---|---|---|
| Prediluted 50% | 0-91275-07998 | 1 U.S. Gallon |
$36.00 |
| 100% Coolant | 0-91275-07997 | 1 U.S. Gallon |
$55.00 |
| Coolant Life Extender | 0-91275-07999 | 1 U.S. Quart | $20.00 |
| Cooling System Flush | 0-91275-02610 | 1 U.S. Gallon | $50.00 |
| Distilled Water | 0-91275-00000 | 1 U.S. Gallon | $10.00 |
| Synthetic Water | 0-91275-00006 | 1 U.S. Gallon | $15.00 |
| Scale Remover Powder | 0-91275-34543 | 340 Grams | $17.00 |
| Coolant Sealer Liquid | 0-91275-00845 | 250mL | $10.00 |
*) U.S. Retail Price includes FREE shipping by FedEx Ground Service in USA & Canada.
*) U.S. Retail Price includes FREE shipping to Europe, Asia, Australia, South America by USPS Economy Air Parcel Service - Typical delivery time 5 to 15 days.
![]()
FREE shipping of Distilled Water is available ONLY with Coolant purchase.
![]()
![]()
|
Send mail to synlube@aol.com with questions or comments about this web site.
Lube-4-Life®
is a Registered Trademark of SynLube, Inc.
|